HomeProductsSingle Phase UPSGT11 Tower Online Uninterruptible Power Supply 1kVA 2kVA 3kVA
  • 1-3kVA single phase high frequency uninterruptible power supply tower type-Gottogpower (2)
  • 1-3kVA single phase high frequency uninterruptible power supply tower type-Gottogpower
  • 3kVA tower type UPS gottogpower actual picture

GT11 Tower Online Uninterruptible Power Supply 1kVA 2kVA 3kVA

Power range:1~3kVA 1P/1P, online double conversion Single Phase In Single Phase Out Tower Online Uninterruptible Power Supplies (UPS) 1KVA 2KVA 3KVA Ups Power Supply With In-built Battery Or External Battery

Intelligent charging management, effectively improving the life time of battery

Smaller size with higher power density

12A charger for option, charging for large capacity batteries

High efficiency, up to 96%

Inquire Now
  • 1-3kVA single phase high frequency uninterruptible power supply tower type-Gottogpower (2)
  • 1-3kVA single phase high frequency uninterruptible power supply tower type-Gottogpower
  • 3kVA tower type UPS gottogpower actual picture

Share:

  • Introduction

  • Parameters

  • Single Phase In Single Phase Out Tower Online Uninterruptible Power Supplies (UPS)1KVA 2KVA 3KVA
  • Ups Power Supply With In-built Battery Or External Battery
  • Power range:1~3kVA
  • Operation:1P/1P, online double conversion
  • Applications:Government, Finance, IT, Education, Transportation, Broadcasting, Medical, Energy, etc.
  • High efficiency up to 96%.
  • Output PF=1, high load adaptability.
  • Wide input voltage range of 110~300Vac.
  • Max charging current up to 12A.
Model GT1101TB GT1101TL GT1102TB GT1102TL GT1103TB GT1103TL
Rate Power 1kVA/1kW 1kVA/1kW 2kVA/2kW 2kVA/2kW 3kVA/3kW 3kVA/3kW
Cold start Default output 50/60Hz
Input voltage range 110~300VAC;100% load@176VAC~276VAC, 100%~50% power derating@110VAC~176VAC, 50% load@276VAC~300VAC
Input power factor ≥0.99
Frequency range 50/60±5Hz(default), ±3Hz/±10Hz(settable)
Output power factor 1
Output Rate output 220/230/240VAC
Load response ≤5% (0% - 100% -0%)
Recovery time ≤40ms (0% - 100% -0%)
 THDu ≤1%, linear load ;≤ 5% , non-linear load according to IEC62040-3
Transfer time Main to BAT 0
INV to BYP 4ms
Crest factor 3:1
Efficiency-normal mode Max 96%
Noise (1 meter) 43dB@<60%load, 47dB@>60%load  <50dB@<60%load,<55dB@>60%load  <50dB@<60%load,<55dB@>60%load
Overload Normal mode 102%~110%: 30mins, 110%~125%:10mins, 125%~150%: 30 seconds
Battery mode 102%~110%: 1min, 110%~125%: 10 seconds, 125%~150%:5 seconds
Bypass mode <130%: long time, 130%~150%:10mins, 150%~180%:5 seconds
Battery Model 12VDC/7Ah Depend on
external battery
12VDC/7Ah Depend on
external battery
12VDC/7Ah Depend on
external battery
Quantity 3 6 8
Max charging 1A 1-12A(settable) 1A 1-12A(settable) 1A 1-12A(settable)
Rate voltage 36VDC 72VDC 96VDC
Standard RS232, EPO
Option SNMP card, AS400, USB, RS485, BMS by dry contact, Air filter
Dimension,(W*D*H)mm 144*355*226  190*400*328  144*398*223  190*400*328  144*398*223
Weight (kg) 10.5 4.5 20.5 6 25 6