HomeProductsModular Online UPSGT-18LPM 208V Modular Online UPS Power Supply 72/108kVA
  • 108kVA 108kW on-line ups power supply rack mounted modular 208VAC-Gottogpower
  • 2U-power-modular-for-rack-mounted-power-supply 108V

GT-18LPM 208V Modular Online UPS Power Supply 72/108kVA

72kVA 108kVA Rack Mounted Modular Uninterruptible Power Supply(ups) 208VAC low voltage,meet the requirements of Europe and America 3P/3P,3P/1P,1P/1P,Online double conversion Application for Government, Finance, IT, Education, Transportation, Broadcasting, Medical, Energy, etc.

Mounted in 19 inch rack, or stand alone.

7 inch touch LCD, with IoT functions.

High reliability and environment adaptability, with protection of components level.

Extreme high power density,30kW in 2U, friendly for space and maintenance.

Option of 30A charger module for long backup applications

Tag:

Inquire Now
  • 108kVA 108kW on-line ups power supply rack mounted modular 208VAC-Gottogpower
  • 2U-power-modular-for-rack-mounted-power-supply 108V

Share:

  • Introduction

  • Parameters

Full-load-temperature-rise-test
Power-module-distribution-diagram

Modular Uninterruptible power supply(ups) highly integrated new PCB design, truly achieving minimalist assembly, reasonable power and signal layout, reducing signal interference, improving heat dissipation efficiency and design margin.

Compatible with upperlower incoming and outgoing lines
Compatible with upperlower incoming and outgoing lines(1)
Compatible with upperlower incoming and outgoing lines(2)

Compatible with upper/lower incoming and outgoing lines

Model GT72/18LPM GT108/18LPM
Rate Power 72kVA/72kW 108kVA/108kW
Main
input
Input 3P5W (3P+N+PE)
Rate Voltage 200/208/220VAC(L-L)
Rate Freq. 50/60Hz
Input PF >0.99
Current distortion THDi<3%(100% Linear load)
Voltage range 166-261VAC(L-L)full load; 125-166VAC (L-L) power derate from 100% to 75%
Freq. range 40-70Hz
Battery Rate voltage ±120VDC
Charging capacity 20%*Pout
Charging accuracy ±1%
Bypass Rate voltage 200/208/220VAC(L-L)
Voltage range Range: -40%- +25% , Settable, default -20% +15%
Overload 110%, long time operation110%< load<125%, 5 mins
125%<load<150%,1 min
>150%,1 second
Inverter Rate voltage 200/208/220VAC(L-L)
Rate Freq. 50/60Hz
Output PF 1
Voltage accuracy ±1.0%
Load response <5% (20% - 80% -20% step load)
Recovery time < 20ms (0% - 100% -0% step load)
Output THDu <1%(linear load),<5% (non-linear load according to IEC 62040-3)
Overload 110%,1 hour 125%,10 mins 150%,1 min >150%,200ms
Frequency accuracy 0.001
Synchronize window Settable ±0.5Hz-±5Hz default ±3Hz
Slew rate Settable 0.5Hz/S-3Hz/S default 0.5Hz/S
Phase Accuracy 120°±0.5
System Efficiency Normal Mode96%;Battery mode96%
Display LED + 7 inch touch LCD
Certification- Safety IEC62040-1, IEC60950-1
Certification- EMS IEC62040-2 IEC61000-4-2(ESD) IEC61000-4-3(RS) IEC61000-4-4 (EFT) IEC61000-4-5 (Surge)
IP degree IP20
Configuration USB, RS232, RS485, Dry contact, Cold start
Option SNMP card, AS400 card, Parallel kit, LBS, Air filter, Bottom entry kit, Wheels kit
Environment 0-40 (operation) -25 ~70 (storage) 0-95% (Humidity, non-condensing)
Noise(dB)(1 meter) 65dB @ 100% load, 62dB @ 45% load
Dimention cabinet(W*D*H)mm 482*816*796 (18U wheels not included) 482*816*1018(23U wheels not included)
module(W*D*H)mm 440*678*85 (2U)

Consulting Products