HomeProductsPrecision and ITGT-Base Station Precision Cooling 6/8/13/17/20kW
  • 4-20kw-Top air supply Base Station Cooling gottogpower
  • 4-20kw-Downward air supply base station cooling gottogpower(1)
  • 6kW7.5kW12.5kW17kW20kW Base Station precision air conditioner -Gottogpower (2)
  • base station precision air cooling gottogpower
  • base station precision air cooling gottogpower

GT-Base Station Precision Cooling 6/8/13/17/20kW

GOTTOGPOWER Base Station series of new small and medium-sized computer room precision air conditioning are specially designed for small and medium-sized data center room environments, providing a stable, reliable and precise temperature and humidity environment for small and medium-sized data centers. It has the characteristics of large air volume, small enthalpy difference, high sensible heat ratio, high energy efficiency ratio and high reliability, which can provide guarantee for the uninterrupted operation of small and medium-sized data centers 24 hours a day, 365 days a year. The GOTTOGPOWER Base Station series of new computer room precision air conditioning have a cooling capacity ranging from 6 to 20kw, and can be made into single cooling type, heating type, humidification type, constant temperature and humidity type, etc. to meet different environmental temperature and humidity control needs. Inquire Now
  • 4-20kw-Top air supply Base Station Cooling gottogpower
  • 4-20kw-Downward air supply base station cooling gottogpower(1)
  • 6kW7.5kW12.5kW17kW20kW Base Station precision air conditioner -Gottogpower (2)
  • base station precision air cooling gottogpower
  • base station precision air cooling gottogpower

Share:

  • Introduction

  • Parameters

  • The product is designed with large air volume, small enthalpy difference and high sensible heat ratio. The sensible heat ratio is greater than 90%, which meets the environmental requirements of high sensible heat in the computer room and provides a stable temperature and humidity environment for the computer room.
  • Equipped with a world-renowned brand of high-energy-efficiency compressor, continuous compression, no reciprocating parts, and low failure rate.
  • It is equipped with an electronic expansion valve to accurately adjust the refrigerant flow according to the refrigeration working conditions, with fast adjustment speed and high precision.
  • Equipped with an EC fan, the EC fan can operate at stepless speed according to the refrigeration conditions, ensuring control accuracy while reducing fan energy consumption. In addition, the EC fan can cooperate with the electronic expansion valve during dehumidification conditions to increase the dehumidification capacity and reduce the energy waste of over-compensation of electric heating caused by low temperature during dehumidification, which is efficient and energy-saving.
  • The outdoor fan adopts a stepless speed-adjustable fan, which can adjust the speed according to the pressure of the refrigeration system, reducing the operating pressure fluctuation of the refrigeration system, improving the operation stability of the refrigeration system, and reducing the energy consumption of the entire machine.
  • The control system has a group control function and uses a more reliable CAN bus, which can centrally control 32 devices. It has functions such as rotating backup, competitive operation avoidance, hot backup, and fault backup to achieve overall energy saving for the equipment in the computer room.
  • The refrigeration system uses R410A refrigerant, which is in line with modern environmental protection concepts.
  • All components are from world-famous brands, and the components and systems are designed to be stable. The equipment has been tested under laboratory extreme conditions and operates reliably.
  • Complete alarm protection function, including:
  • --Power protection
  • --Water leakage protection
  • --Temperature and humidity over-limit alarm
  • --Dirty filter alarm
  • --System component protection
  • --Other alarm protection
  • Intelligent power-on auto-start function, when the power comes back after a power outage, the unit will start automatically. After starting, it can operate according to the parameters before shutdown. And the start-up time can be adjusted to avoid impact on the power grid when multiple devices in the same computer room are started at the same time.
  • The standard RS485 interface provides free communication protocol and can be connected to the dynamic environment system to achieve remote monitoring.
  • Low temperature components, long connecting pipe components, etc. can be selected to ensure reliable operation of the unit in more severe on-site conditions.
  • The use of electrode humidifier has the advantages of fast humidification speed and high humidity control accuracy.
  • The standard configuration is a 4.3-inch color touch screen, which can display in real time:
  • --Component operating status
  • --Part runtime
  • --Air conditioner running time
  • --Real-time alarm
  • --Historical alarm
  • --Temperature and humidity curve
  • --Other display content
  • The control system has multi-level password protection, and different personnel have different permissions to prevent irrelevant personnel from adjusting parameters.
  • Intelligent judgment distinguishes different levels of alarm information, and can send out different alarm signals according to different levels of alarms.
  • It has group control functions such as rotation and backup, and can realize automatic switching between the main machine and the backup machine at the set time.
  • Using standard RS485 monitoring interface, standard RS485 protocol can be provided free of charge.
  • It can realize remote setting, monitoring unit operating status and alarm information.
  • Equipped with a semiconductor PTC electric heater, which has positive temperature coefficient characteristics to avoid the redness of the surface caused by other electric heaters, and is equipped with safety protection functions for safer operation.
  • Standard threaded quick connectors enable quick on-site installation without welding.
  • Match the best air supply method according to the site conditions.
  • Select the auxiliary heating or humidification function configuration according to the needs of the environment.
chiller
cooling
heating
Indoor Unit Parameters
Model GTBS006 GTBS008 GTBS013 GTBS017 GTBS020
Function Single Cooling or Single Cooling + Electric Heating or Constant Temperature and Humidity
Air supply method F F F/D F/D F/D
Power 220VAC/1Ph/50Hz 380VAC/3Ph/50Hz 380VAC/3Ph/50Hz 380VAC/3Ph/50Hz 380VAC/3Ph/50Hz
Total cooling capacity 5.8kW 7.6kW 12.6kW 17.5kW 20.2kW
Sensible cooling capacity 5.2kW 6.9kW 11.3kW 15.7kW 18.2kW
Electric heating type PTC electric heater
Heating capacity According to different power, welcome to inquire
Humidification type Electrode humidifier
Humidification capacity According to different power, welcome to inquire
Compressor*1pc Fixed frequency compressor
Refrigerant type R410A
throttling type Electronic expansion valve
Supply air fan*1pc Back-tilt centrifugal EC fan
Airflow 1900m³/h 2400m³/h 3800m³/h 5300m³/h 5700m³/h
Outlet air pressure Standard residual pressure is 20Pa, adjustable from 20-300Pa
Air filter G4 plate type filter
Noise(dBA) 65 65 66 67 68
Indoor unit dimention (W*D*H)mm 600*510*1900 600*580*1900 600*580*1900 750*660*1900 750*660*1900
Weight 110kg 116kg 135kg 162kg 166kg
F:Come forward to blow the air,D:Bottom outlet
The indoor return air dry bulb temperature is 24°C, the relative humidity is 50%, and the indoor dry bulb temperature is 35°C.
The above table is only part of the parameters. The specific configuration is subject to the actual nameplate purchased.
Outdoor Unit Parameters
Model GTCH081 GTCH121 GTCH191 GTCH241 GTCH291
Power 220VAC/1Ph/50Hz
Installation method Vertical Horizontal/vertical
Condensing fan type Single phase asynchronous motor+Axial flow blade Single phase axial flow fan
Number of fans 1 1 2 1 1
Airflow 3000m³/h 4000m³/h 7000m³/h 8500m³/h 9000m³/h
Input power 0.16kW 0.17kW 0.38kW 0.6kW 0.61kW
Input current 0.62A 0.65A 1.7A 3.4A 3.4A
Speed regulation method Stepless speed regulation
Noise(dBA) 53 55 58 65 68
outdoor unit dimention (W*D*H)mm 835*310*710 960*390*800 960*390*1270 1115*520*1065 1115*545*1065
Weight 45kg 48kg 65kg 90kg 100kg

Consulting Products

Free to contact us