250kVA 300kVA Smart Modular UUninterruptible Power Supply(ups) 3P/3P,Online double conversion Application for Government, Finance, IT, Education, Transportation, Broadcasting, Medical, Energy, etc.

Fully digital control, flexible and robust.

10 inch touch LCD, with IoT functions.

High reliability and environment adaptability, with protection of components level.

Extreme high power density, 30kW in 2U, friendly for space and maintenance.

Option of 30A charger module for long backup applications.

Inquire Now
  • 300kVA 30power module uninterruptible power supply smart modular-Gottogpower

Share:

  • Introduction

  • Parameters

Excellent temperature design margin - full load temperature rise test for GT250/25SPM and GT300/30SPM

Power-module-distribution-diagram

GT250/25SPM and GT300/30SPM Modular Uninterruptible Power supply highly integrated new PCB design, truly achieving minimalist assembly, reasonable power and signal layout, reducing signal interference, improving heat dissipation efficiency and design margin.

IoT application scenarios
Model GT250/25SPM GT300/30SPM
Rate Power 250kVA/250kW 300kVA/300kW
Main
input
Input 3P5W (3P+N+PE)
Rate Voltage 380/400/415VAC(L-L) 220/230/240VAC(L-N)
Rate Freq. 50/60Hz
Input PF >0.99
Current distortion THDi<3%(100% Linear load)
Voltage range 304 478VAC(L-L)full load 304 228VAC (L-L) power derate from 100% to 75%
Freq. range 40-70Hz
Battery Rate voltage ±240VDC
Charging capacity 20%*Pout
Charging accuracy ±1%
Bypass Rate voltage 380/400/415VAC(L-L)220/230/240VAC(L-N)
Voltage range Range: -40%- +25% , Settable, default -20% +15%
Overload 110%, long time operation110%< load<125%, 5 mins
125%<load<150%,1 min>150%,1 second
Inverter Rate voltage 380/400/415VAC(L-L) 220/230/240VAC(L-N)
Rate Freq. 50/60Hz
Output PF 1
Voltage accuracy ±1.0%
Load response <5% (20% - 80% -20% step load)
Recovery time < 20ms (0% - 100% -0% step load)
Output THDu <1%(linear load),<5% (non-linear load according to IEC 62040-3)
Overload 110%,1 hour 125%,10 mins 150%,1 min >150%,200ms
Frequency accuracy 0.001
Synchronize window Settable ±0.5Hz-±5Hz default ±3Hz
Slew rate Settable 0.5Hz/S-3Hz/S default 0.5Hz/S
Phase Accuracy 120°±0.5
System Efficiency Normal Mode96%;Battery mode96%
Display LED + 10 inch touch LCD
Certification- Safety IEC62040-1, IEC60950-1
Certification- EMS IEC62040-2 IEC61000-4-2(ESD) IEC61000-4-3(RS) IEC61000-4-4 (EFT) IEC61000-4-5 (Surge)
IP degree IP20
Configuration USB, RS232, RS485, Dry contact, Cold start,Air filter
Option SNMP card, AS400 card, Parallel kit, LBS
Environment 0-40 (operation) -25 ~70 (storage) 0-95% (Humidity, non-condensing)
Noise(dB)(1 meter) 65dB @ 100% load, 62dB @ 45% load
Dimention cabinet(W*D*H)mm 600*1000*2000
module(W*D*H)mm 440*555*85 (2U)