HomeProductsThree Phase UPSGT33 Rack Online UPS Power Supply 10/15/20/30/40/60kVA
  • 10-40kVA Rack-Mounted high frequency uninterruptible power supply-Gottogpower
  • 10-40kVA Rack-Mounted high frequency uninterruptible power supply-Gottogpower
  • Rack Uninterruptible Power Supply10~40kVA

GT33 Rack Online UPS Power Supply 10/15/20/30/40/60kVA

🔺10kVA/15kVA/20kVA/30kVA/40kVA Rack/60kVA Mounted Uninterruptible Power Supply(ups).
🔺3P/3P,3P/1P,1P/1P, Online double conversion.
🔺Application for Government, Finance, IT, Education, Transportation, Broadcasting, Medical, Energy, etc.

Mounted in 19 inch rack, or install as tower UPS.

7 inch touch LCD with IoT functions.

Flexible configuration as 3/3,3/1,1/1.

High power density, small volume, 30kW in 3U.

High reliability and environment adaptibility.

Inquire Now
  • 10-40kVA Rack-Mounted high frequency uninterruptible power supply-Gottogpower
  • 10-40kVA Rack-Mounted high frequency uninterruptible power supply-Gottogpower
  • Rack Uninterruptible Power Supply10~40kVA

Share:

  • Introduction

  • Parameters

  • Download

  • Core Performance Advantages
  1. Super Power Adaptability

–Low Harmonic Interference: Input THDi <3% (100% linear load);

–High Power Factor: >0.99.

  1. Pure and stable output
  • High-precision voltage stabilization: voltage precision: ±1.0.
  1. Frequency Accuracy: ±0.1%
  • Pure Sine Wave: Linear Load THDu: <1%; Non-linear Load THDu: <5%;
  • Extremely Fast Dynamic Response.
  1. Strong overload capability
  • 110% load: 1 hour duration; 125% load: 10 minutes duration; 150% load: 1 minute duration.
GT33 Rack Online UPS Power Supply 10/15/20/30/40kVA

5. Intelligent Battery Management

  • Precise Charging Control: Charging Voltage Accuracy: ±1%
  • High Voltage DC System: 240VDC

6. Interaction and Expansion

GT33 Rack Online UPS Power Supply 10/15/20/30/40kVA

• Standard communication interfaces: USB, RS232, RS485, dry contact

• Optional expansion modules: SNMP card, AS400 card, Parallel kit, LBS, Air filter, Cold start

Model GT33010RL GT33015RL GT33020RL GT33030RL GT33040RL GT33060RL
Rate Power 10kVA 15kVA 20kVA 30kVA 40kVA 60kVA
Main
input
Input 3P5W (3P+N+PE)
Rate Voltage 380/400/415VAC(L-L) 220/230/240VAC(L-N)
Rate Freq. 50/60Hz
Input PF >0.99
Current distortion THDi<3%(100% Linear load)
Voltage range 304 478VAC(L-L)full load 304 228VAC (L-L) power derate from 100% to 75%
Freq. range 40-70Hz
Battery Rate voltage ±240VDC
Charging capacity 20%*Pout
Charging accuracy ±1%
Bypass Rate voltage 200/208/220VAC(L-L)
Voltage range Range: -40%- +25% , Settable, default -20% +15%
Overload 110%, long time operation110%< load<125%, 5 mins125%<load<150%,1 min>150%,1 second
Inverter Rate voltage 380/400/415VAC(L-L) 220/230/240VAC(L-N)
Rate Freq. 50/60Hz
Output PF 1
Voltage accuracy ±1.0%
Load response <5% (20% - 80% -20% step load)
Recovery time < 20ms (0% - 100% -0% step load)
Output THDu <1%(linear load),<5% (non-linear load according to IEC 62040-3)
Overload 110%,1 hour 125%,10 mins 150%,1 min >150%,200ms
Frequency accuracy 0.1%
Synchronize window Settable ±0.5Hz-±5Hz default ±3Hz
Slew rate Settable 0.5Hz/S-3Hz/S default 0.5Hz/S
Crest factor 3: 1
Phase Accuracy 120°±0.5
System Efficiency Normal Mode≥96%;Battery mode≥96%
Display LED + 7 inch touch LCD
Certification- Safety IEC62040-1, IEC60950-1
Certification- EMS IEC62040-2 IEC61000-4-2(ESD) IEC61000-4-3(RS) IEC61000-4-4 (EFT) IEC61000-4-5 (Surge)
IP degree IP20
Configuration USB, RS232, RS485, Dry contact
Option SNMP card, AS400 card, Parallel kit, LBS, Air filter, Cold start
Environment 0-40 (operation) -25 ~70 (storage) 0-95% (Humidity, non-condensing)
Dimention (W*D*H)mm 440*774*130 (3U) 440*788*174 (4U) 444*910*223(5U)

Consulting Products

Free to contact us