HomeProductsThree Phase UPSGTS-Pro Tower Series Online Tower UPS Power Supply 6kVA/10kVA/15kVA/20kVA
  • GOTTOGPOWER Tower Series 6kVA 10kVA 15kVA 20kVA 3/1 Tower UPS
  • GOTTOGPOWER Tower Series 6kVA 10kVA 15kVA 20kVA 3/1 Tower UPS

GTS-Pro Tower Series Online Tower UPS Power Supply 6kVA/10kVA/15kVA/20kVA

🔺6kVA/10kVA/15kVA/20kVA Tower UPS.
🔺3P/1P,1P/1P,Online double conversion.
🔺High-speed DSP control for system performance & protection.
🔺Online double conversion, full digital control.
🔺Application for Government, Finance, IT, Education, Transportation, Broadcasting, Medical, Energy, etc.

Intelligent battery management.Wide range of input voltage tolerance.

4.3-inch color touch screen easy operation.

Auto fault waveform recording.

Output PF=1,high load adaptability.Self-aging function to save test energy.

Inquire Now
  • GOTTOGPOWER Tower Series 6kVA 10kVA 15kVA 20kVA 3/1 Tower UPS
  • GOTTOGPOWER Tower Series 6kVA 10kVA 15kVA 20kVA 3/1 Tower UPS

Share:

  • Introduction

  • Parameters

  • Download

GTS-Pro Tower Series is a compact three-phase input / single-phase output online double-conversion UPS designed for small to medium critical infrastructure. With output power factor 1.0 and advanced DSP control, it delivers high reliability, strong grid adaptability, and intelligent battery management for continuous power protection.

● Wide Voltage Input, Adjustable Output

Input voltage (190-499VAC) auto-adapts to global grids, while selectable output (220/230/240VAC) enables transformer-free compatibility with regional equipment, streamlining worldwide deployment.

Ultra-wide-input-voltage-adjustable-output
GTS-Pro Tower Series Online Tower UPS Power Supply 6kVA/10kVA/15kVA/20kVA

● Low Harmonic Interference, Safeguarding Sensitive Equipment: THDi ≤1% for linear loads, ≤3% for non-linear loads

Ultra-low harmonic distortion eliminates waveform distortion, ensuring distortion-free operation for medical/lab equipment and preventing malfunctions or latent damage.

● Pure sine wave, supports cold start without mains power

Pure sine wave power, compatible with precision equipment, reduces losses. Cold start without mains starts directly in outages, suits off-grid emergencies. Their combination enhancing equipment reliability and practicality.

  • Applications

Government, finance, IT and server rooms, education, transportation, broadcasting, medical, energy, and industrial systems.

FAQ:

  • Q: What is the power range of the GTS-Pro Tower Series UPS?
    A: The GTS-Pro Tower Series covers 6kVA, 10kVA, 15kVA, and 20kVA models, delivering up to 20kW with output power factor 1.0, making it suitable for small to medium critical load applications.
  • Q: What input and output configurations are supported?
    A: The system supports 3P/1P and 1P/1P configurations, allowing flexible deployment in sites with three-phase input infrastructure and single-phase load requirements.
  • Q: Does the GTS-Pro Tower UPS support remote monitoring?
    A: Yes. The UPS supports remote monitoring via optional SNMP card, dry contact board, and APP/WiFi/Bluetooth modules. Standard communication interfaces include RS232 and RS485 for integration with monitoring systems.
  • Q: What is the battery configuration?
    A: The system supports external battery banks with 16–24 batteries selectable. Some models support internal batteries (16 pcs 12V/7Ah or 12V/9Ah). The default battery voltage is 192VDC and can be adjusted up to 288VDC. Charging current is settable up to 8A, with an optional 12A charger.
  • Q: How does the UPS perform under unstable grid conditions?
    A: The UPS supports a wide input voltage range of 190–499VAC (L-L) with automatic load derating and frequency self-adaptation (50/60Hz), ensuring stable operation even under fluctuating utility power.
  • Q: What overload capability does the system provide?
    A: In normal mode, the UPS supports 110% load for 60 minutes, 125% load for 10 minutes, and 150% load for 30 seconds, ensuring reliable protection during transient overload conditions.
  • Q: Does the system support cold start?
    A: Yes, cold start is supported, allowing the UPS to start directly from battery power without utility input.

Our Factory and Cases

We welcome you to visit our factory to explore the quality and capabilities of our products firsthand.

Model GSS06B-P GSS10B-P GSS06L-P GSS10L-P GTS10L-P GTS15L-P GTS20L-P
Rate Power 6kVA/6kW 10kVA/10kW 6kVA/6kW 10kVA/10kW 10kVA/10kW 15kVA/15kW 20kVA/20kW
Cold start Default output 50/60Hz
Input voltage range 110-288VAC (L-N), 100% load@>176VAC;90% l0ad@>154VAC; 75% l0ad@>132VAC; 50% l0ad@>110VAC 190-499VAC(L-L),100% load@>305VAC;90% load@>266VAC; 75% load@>228VAC;50% load@>190VAC
Input power factor ≥0.99
Frequency range 40-70Hz
Output frequency 50/60Hz,self adaption
Output power factor
Rate output 220/230/240VAC
Load regulation ±1%
Output THDu ≤1%,Linear load; ≤5%,non-linear load
Transfer time-INV to BYP 0ms
Efficiency- normal mode 95.5% 94.50% 95%
Efficiency-ECO mode 98%
Noise(1 meter) <58dB <62dB
Overload(normal mode) 110%:60mins; 125%:10mins; 150%:30 seconds
Battery Mode 16 pcs 12V/7Ah 16 pcs 12V/9Ah External batteries,16-24 settable
Quantity
Max charging 1A 8A, settable
Rate voltage Default 192VDC, 192-288VDC settable
Standard RS232,RS485
Option SNMP card, dry contact board, APP/WiFVBluetooth, parallel kit,  12A charger,  Maintenance bypass switch
Dimension
W*D*H(mm)
Cabinet 190*494*550 190*494*338 190*514*500
Max. 190*606*550 190*606*338 190*564*500