GT-Liquid Series Cold Plate In Row CDU Cooland Distribution Units 30~600kVA

This in row liquid cooling distribution unit is a high-efficiency solution designed for modern data centers. It is compatible with ASHRAE W4 water temperature design, enabling year-round free cooling across different climates. The system uses built-in pressurized make-up technology to maintain coolant volume, and intelligent anti-condensation control ensures safe and reliable operation of the secondary loop. Its rack-mounted modular design allows flexible installation close to IT heat sources, reducing piping complexity and enabling fast on-site deployment.

Standard dual power supply with 1+1 redundant circulation pumps, minimizing single points of failure.

7-inch capacitive touchscreen with graphical status display and temperature/pressure curves for intuitive monitoring.

Electric proportional control valves combined with variable-speed circulation pumps deliver precise flow control, achieving steady-state temperature accuracy of ±0.3°C.

Supports group control modes with cold standby and hot standby, enabling scheduled rotation, fault takeover, and cascade operation.

Standard quick-connect couplings, with multiple interface options available.

Inquire Now
  • Cooland Distribution Units Liquid Cold Plate In Row CDU 30 600kVA

Share:

  • Introduction

  • Parameters

  • Download

Application

Medium- and large-scale newly built intelligent computing centers; small-scale newly built and upgraded intelligent computing centers; high-density, high-performance computing deployment applications.

GT-Rack Precision Cooling 3.5/5/7.5/12.5kW

Key Technical Characteristics

We provide complete solutions for the entire deployment process of liquid cooling systems, including design, implementation, operation and maintenance.

in row cdu Cooland Distribution Units
air cooling vs liquid vooling (1)
Air cooling uses air as the heat exchange medium, relying on fans to circulate cool air and remove heat from IT equipment, and it remains the most commonly used cooling method in traditional data centers.
In contrast, liquid cooling uses liquid as the heat transfer medium to absorb and carry away heat more efficiently, either directly or indirectly from heat-generating components.
With the rapid growth of high-density and high-performance computing, liquid cooling has emerged as a more efficient and energy-saving cooling solution.
  • Liquid cooling architecture with higher heat transfer efficiency compared to traditional air cooling.
  • Modular rack-mounted design allows flexible installation at any position within the cabinet.
  • High-efficiency rack-mounted liquid cooling capacity distribution unit designed for standard cabinets and rack architectures.

Our Factory

We welcome you to visit our factory to experience the quality and performance of our products firsthand.

Model In Row Liquid-to-Liquid CDU
Rate Power CDU060CL CDU100CL CDU150CL CDU300CL CDU600CL
Performance Specifications
Heat Exchange Capacity (kW) 60 100 150 300 600
Dimensions (W*D*H)mm 600*1200*2000 1200*1200*2000
Power Specifications 380V 3N~50Hz/60Hz, Dual Power Supply Standard
Rated Power (kW) 0.7 1.5 1.75 3.7 7.7
Full Load Current (A) 2.5 7.1 7.3 13.5 16.3
Net Weight (kg) 235 283 293 372 632
Secondary Side System Parameters
Rated Supply LiquidTemperature (°C) 40
Rated Retur LiquidTemperature(°C) 50
Rated Circulation Flow (m³/h) 5.5 9.1 13.7 27.3 54.6
Available Headat Secondary Side ≥12m ≥15m
Adjustable Range for Secondary Side Supply Temperature 25~45°C
Filter Precision 100μm
Circulation Pump Variable Speed Pump, Standard 1+1 Redundant
Circulating Medium Deionized Water, Compatible with 25% Glycol Solution and Other Compatible Coolants
Refill System Built-in Automafic Refil System
Maximum Operating Pressure 50 Bar
Pipe Connection Size & Type DN32,
Quick-install Clamp
DN50,
Quick-install Clamp
DN65,
Quick-install Clamp
DN80,
Quick-install Clamp
Primary Side System Parameters
Rated Return Liquid Temperature (°C) 35
Rated Supply Liquid Temperature (°C) 45
Rated Circulation Flow(m³/h) 5.5 9.1 13.7 27.3 54.6
Allowed Inlet Liquid Temperature(Primary Side) 10-35°C
Circulating Medium Deionized Water, Compatible with 30% Glycol Solution and Other Compatible Coolants,Flexible Selection Based on Regional Conditions
Filter Requirement Precision ≤270μm
Rated Pressure Drop Requirement(Primary Side) ≤80 kPa
Maximum Operating Pressure 10.0 Bar
Pipe Connection Size& Type DN32,
Quick-install Clamp
DN50,
Quick-install Clamp
DN65,
Quick-install Clamp
Model In Row Liquid-to-Liquid CDU
Rate Power CDU030CA CDU060CA
Performance Specifications
Heat Exchange Capacity (kW) 30 60
Dimensions (W*D*H)mm 600*1200*2000
Power Specifications 220V/1N-50Hz/60Hz, Dual Power Supply Standard
Rated Power (kW) 2.9 3.8
Full Load Current (A) 25.5 34.2
Net Weight (kg) 310 421
Secondary Side System Parameters
Rated Supply Liquid Temperature(°C) 40
Rated Retumr Liquid Temperature(°C) 50
Raled Circulation Flow (m³/h) 2.8 5.5
Available Headat Secondary Side ≥10m
Adjustable Range for Secondary Side Supply Temperature 25-45°C
Fillter Precision 100μm
Circulation Pump Variable Speed Pump, Standard 1+1 Redundant
Circulating Medium Deionized Water, Compatible with 25% Ethanol Solution and Other Compatible Coolants
Refill System Buil-in Automatic Refill System
Maximum Operating Pressure 50 Bar
Pipe Connection Size & Type DN20,
Quick-install Flange
DN25,
Quick-install Flange
Primary Side System Parameters
Rated Inlet AirTemperature (°C) 25