HomeProductsSingle Phase UPSGT11 Series 6~10kVA Single Phase Rack UPS
  • GT11 Series 6~10kVA Online Rack UPS
  • GT11 Series 6~10kVA Online Rack UPS
  • GT11 Series 6~10kVA Online Rack UPS

GT11 Series 6~10kVA Single Phase Rack UPS

🔺Power range: 6~10kVA.
🔺Operation: 1P/1P, online double conversion.
🔺Applications: Government, Finance, IT, Education, Transportation, Broadcasting, Medical, Energy, etc.

Inquire Now
  • GT11 Series 6~10kVA Online Rack UPS
  • GT11 Series 6~10kVA Online Rack UPS
  • GT11 Series 6~10kVA Online Rack UPS

Share:

  • Introduction

  • Parameters

  • Download

Double-conversion-online-UPS

● Online double conversion, full digital control

Online double conversion provides continuous clean power and zero transfer time during outages, fully isolating critical loads from all utility power problems (sags, surges, noise, frequency shifts).

● Output PF=1,high load adaptability

Delivers maximum real power efficiency by eliminating wasteful reactive power, significantly reducing energy costs. Seamlessly powers diverse critical loads, including modern servers with demanding Active PFC power supplies, variable-speed drives, and sensitive electronics, without derating or performance compromise, provides stable, efficient power under all operating conditions.

GOTTOGPOWER UPS Output PF=1, high load adaptability
3-level topology

● 3-level topology, high performance and efficiency

The 3-level topology generates a smoother, more refined output waveform with significantly lower Total Harmonic Distortion compared to traditional 2-level designs, improving power quality for sensitive equipment. And by utilizing multiple voltage steps during switching, it achieves reduced switching losses and lower electromagnetic interference, leading to higher overall operational efficiency.

  • Intelligent battery management.
  • Wide range of input voltage tolerance.
  • Adapt to half-wave load.
  • Auto fault waveform recording.
  • Self-aging function to save test energy 10kW in 2U, high power density.
Model GT1106RB GT1106RL GT1110RB GT1110RL
Rate Power 6kVA/6kW 6kVA/6kW 10kVA/10kW 10kVA/10kW
Cold start Default output 50/60Hz
Input voltage range 110~288VAC;100% load@>176VAC;90% load@>154VAC;75% load@>132VAC;50% load@>110VAC
Input power factor ≥0.99
Frequency range 40-70Hz
Output power factor 1.0 
Output Rate voltage 220/230/240VAC,200/208VAC(PF=0.9)
Load response ≤5% (0% - 100% -0%)
Recovery time ≤40ms (0% - 100% -0%)
THDu ≤1%, linear load ;≤ 5% , non-linear load according to IEC62040-3
Transfer time-Main to Battery 0ms
Transfer time-INV to BYP 0ms
Crest factor 3:1
Battery type 12VDC/7Ah External battery 12VDC/9Ah External battery
Battery Number 16PCS 16-24 PCS settable 16PCS 16-24 PCS settable
Battery voltage 192VDC (default),settable
Max charging 1A 8A 1A 8A
Efficiency –normal mode Max 95.5%
Noise (1 meter) <58dB
Overload Normal 105%~110%: 10mins,111%~125%: 1 min,126%~150%: 30 seconds
ECO mode <125%: long time,126%~130%:5mins,131%~150%:1min,>150% :200ms
Communication RS232, EPO, RS485
Option AS400, USB, SNMP card, 12A charger, Parallel kit, Air filter
Dimension ,W*D*H(mm) 440*660*172 440*580*86 440*660*172 440*580*86
Weight (kg) 63 16 63.0 18

 

Consulting Products

Free to contact us