LarProdutosUPS trifásicoFonte de alimentação UPS online da série GTS-Pro Tower, 6kVA/10kVA/15kVA/20kVA
  • GOTTOGPOWER Tower Series 6kVA 10kVA 15kVA 20kVA 3/1 Tower UPS
  • GOTTOGPOWER Tower Series 6kVA 10kVA 15kVA 20kVA 3/1 Tower UPS

Fonte de alimentação UPS online da série GTS-Pro Tower, 6kVA/10kVA/15kVA/20kVA

🔺6kVA/10kVA/15kVA/20kVA Tower UPS.
🔺3P/1P,1P/1P,dupla conversão online.
🔺High-speed DSP control for system performance & protection.
🔺Online double conversion, full digital control.
🔺Aplicação para governo, finanças, TI, educação, transporte, radiodifusão, medicina, energia, etc.

Gerenciamento inteligente de bateria. Ampla faixa de tolerância de tensão de entrada.

4.3-inch color touch screen easy operation.

Gravação automática de forma de onda de falha.

Saída PF=1, alta adaptabilidade de carga. Função de autoenvelhecimento para economizar energia de teste.

Pergunte agora
  • GOTTOGPOWER Tower Series 6kVA 10kVA 15kVA 20kVA 3/1 Tower UPS
  • GOTTOGPOWER Tower Series 6kVA 10kVA 15kVA 20kVA 3/1 Tower UPS

Compartilhar:

  • Introdução

  • Parâmetros

  • Download

GTS-Pro Tower Series is a compact three-phase input / single-phase output online double-conversion UPS designed for small to medium critical infrastructure. With output power factor 1.0 and advanced DSP control, it delivers high reliability, strong grid adaptability, and intelligent battery management for continuous power protection.

● Entrada de tensão ampla, saída ajustável

A tensão de entrada (190-499 VCA) se adapta automaticamente às redes globais, enquanto a saída selecionável (220/230/240 VCA) permite compatibilidade sem transformador com equipamentos regionais, simplificando a implantação mundial.

Tensão de entrada ultra-ampla, saída ajustável
Fonte de alimentação UPS online da série GTS-Pro Tower, 6kVA/10kVA/15kVA/20kVA

● Baixa interferência harmônica, protegendo equipamentos sensíveis: THDi ≤1% para cargas lineares, ≤3% para cargas não lineares

A distorção harmônica ultrabaixa elimina a distorção da forma de onda, garantindo uma operação sem distorção para equipamentos médicos/laboratoriais e prevenindo mau funcionamento ou danos latentes.

● Onda senoidal pura, suporta partida a frio sem alimentação elétrica

A energia de onda senoidal pura, compatível com equipamentos de precisão, reduz perdas. A partida a frio sem a necessidade de alimentação da rede elétrica inicia diretamente em caso de falta de energia, sendo adequada para emergências fora da rede. A combinação dessas tecnologias aumenta a confiabilidade e a praticidade do equipamento.

  • Aplicações

Government, finance, IT and server rooms, education, transportation, broadcasting, medical, energy, and industrial systems.

Perguntas frequentes:

  • P: What is the power range of the GTS-Pro Tower Series UPS?
    UM: The GTS-Pro Tower Series covers 6kVA, 10kVA, 15kVA, and 20kVA models, delivering up to 20kW with output power factor 1.0, making it suitable for small to medium critical load applications.
  • P: What input and output configurations are supported?
    UM: The system supports 3P/1P and 1P/1P configurations, allowing flexible deployment in sites with three-phase input infrastructure and single-phase load requirements.
  • P: Does the GTS-Pro Tower UPS support remote monitoring?
    UM: Yes. The UPS supports remote monitoring via optional SNMP card, dry contact board, and APP/WiFi/Bluetooth modules. Standard communication interfaces include RS232 and RS485 for integration with monitoring systems.
  • P: What is the battery configuration?
    UM: The system supports external battery banks with 16–24 batteries selectable. Some models support internal batteries (16 pcs 12V/7Ah or 12V/9Ah). The default battery voltage is 192VDC and can be adjusted up to 288VDC. Charging current is settable up to 8A, with an optional 12A charger.
  • P: How does the UPS perform under unstable grid conditions?
    UM: The UPS supports a wide input voltage range of 190–499VAC (L-L) with automatic load derating and frequency self-adaptation (50/60Hz), ensuring stable operation even under fluctuating utility power.
  • P: What overload capability does the system provide?
    UM: In normal mode, the UPS supports 110% load for 60 minutes, 125% load for 10 minutes, and 150% load for 30 seconds, ensuring reliable protection during transient overload conditions.
  • P: Does the system support cold start?
    UM: Yes, cold start is supported, allowing the UPS to start directly from battery power without utility input.

Nossa Fábrica e Casos

Convidamos você a visitar nossa fábrica para conhecer em primeira mão a qualidade e as capacidades de nossos produtos.

Modelo GSS06B-P GSS10B-P GSS06L-P GSS10L-P GTS10L-P GTS15L-P GTS20L-P
Taxa de potência 6kVA/6kW 10kVA/10kW 6kVA/6kW 10kVA/10kW 10kVA/10kW 15kVA/15kW 20kVA/20kW
Partida a frio Saída padrão 50/60 Hz
Faixa de tensão de entrada 110-288VAC (L-N), 100% load@>176VAC;90% l0ad@>154VAC; 75% l0ad@>132VAC; 50% l0ad@>110VAC 190-499VAC(L-L),100% load@>305VAC;90% load@>266VAC; 75% load@>228VAC;50% load@>190VAC
Fator de potência de entrada ≥0,99
Alcance de frequência 40-70Hz
Frequência de saída 50/60 Hz, autoadaptação
Fator de potência de saída
Taxa de saída 220/230/240 VCA
Regulação de carga ±1%
Saída THDu ≤1%,Linear load; ≤5%,non-linear load
Transferir tempo-INV para BYP 0ms
Eficiência - modo normal 95.5% 94.50% 95%
Modo Eficiência-ECO 98%
Ruído (1 metro) <58 dB <62dB
Sobrecarga (modo normal) 110%:60mins; 125%:10mins; 150%:30 seconds
Bateria Modo 16 pcs 12V/7Ah 16 pcs 12V/9Ah Baterias externas, 16-24 configuráveis
Quantidade
Carregamento máximo 1A 8A, settable
Tensão de taxa Default 192VDC, 192-288VDC settable
Padrão RS232,RS485
Opção SNMP card, dry contact board, APP/WiFVBluetooth, parallel kit,  12A charger,  Maintenance bypass switch
Dimensão
L*D*A(mm)
Gabinete 190*494*550 190*494*338 190*514*500
Máx. 190*606*550 190*606*338 190*564*500