GTS-Pro Tower Series is a compact three-phase input / single-phase output online double-conversion UPS designed for small to medium critical infrastructure. With output power factor 1.0 and advanced DSP control, it delivers high reliability, strong grid adaptability, and intelligent battery management for continuous power protection.
● Entrada de voltaje amplio, salida ajustable
El voltaje de entrada (190-499 VCA) se adapta automáticamente a las redes globales, mientras que la salida seleccionable (220/230/240 VCA) permite la compatibilidad sin transformador con equipos regionales, lo que agiliza la implementación mundial.


● Baja interferencia armónica, protección de equipos sensibles: THDi ≤1% para cargas lineales, ≤3% para cargas no lineales
La distorsión armónica ultrabaja elimina la distorsión de la forma de onda, lo que garantiza un funcionamiento sin distorsiones de los equipos médicos y de laboratorio y evita fallos de funcionamiento o daños latentes.
● Onda sinusoidal pura, admite arranque en frío sin alimentación de red
La energía de onda sinusoidal pura, compatible con equipos de precisión, reduce las pérdidas. El arranque en frío sin red eléctrica arranca directamente en caso de cortes de suministro, ideal para emergencias fuera de la red. Su combinación mejora la fiabilidad y la practicidad del equipo.
- Aplicaciones
Government, finance, IT and server rooms, education, transportation, broadcasting, medical, energy, and industrial systems.
Preguntas más frecuentes:
- P: What is the power range of the GTS-Pro Tower Series UPS?
A: The GTS-Pro Tower Series covers 6kVA, 10kVA, 15kVA, and 20kVA models, delivering up to 20kW with output power factor 1.0, making it suitable for small to medium critical load applications. - P: What input and output configurations are supported?
A: The system supports 3P/1P and 1P/1P configurations, allowing flexible deployment in sites with three-phase input infrastructure and single-phase load requirements. - P: Does the GTS-Pro Tower UPS support remote monitoring?
A: Yes. The UPS supports remote monitoring via optional SNMP card, dry contact board, and APP/WiFi/Bluetooth modules. Standard communication interfaces include RS232 and RS485 for integration with monitoring systems. - P: What is the battery configuration?
A: The system supports external battery banks with 16–24 batteries selectable. Some models support internal batteries (16 pcs 12V/7Ah or 12V/9Ah). The default battery voltage is 192VDC and can be adjusted up to 288VDC. Charging current is settable up to 8A, with an optional 12A charger. - P: How does the UPS perform under unstable grid conditions?
A: The UPS supports a wide input voltage range of 190–499VAC (L-L) with automatic load derating and frequency self-adaptation (50/60Hz), ensuring stable operation even under fluctuating utility power. - P: What overload capability does the system provide?
A: In normal mode, the UPS supports 110% load for 60 minutes, 125% load for 10 minutes, and 150% load for 30 seconds, ensuring reliable protection during transient overload conditions. - P: Does the system support cold start?
A: Yes, cold start is supported, allowing the UPS to start directly from battery power without utility input.